Modified: February 26 2008

Siphon Breaker Valve

Take advantage of Nature

Are you doing this...

Flow 500l/s
Head 10m
Motor 75kW

Illustration showing normal pump discharge
When you could be doing this...

Flow 500l/s
Head 7m
Motor 50kW

Illustration showing the reduction in pump head acheived through using a siphonic system

Download publications

The two illustrations on the left are for exactly the same application; the first shows a typical installation with a free discharge. The second takes advantage of siphonic recovery, and in so doing, offers a significant reduction in pump head and power.

The concept of siphonic assistance has been around for centuries, but is often overlooked for pumping applications. By submerging the outlet of the discharge pipe, the pump static head is reduced simply to the difference between the sump water level and the discharge surface water level.

Traditionally, this method has been widely used in the Land Drainage industry, but can equally be used in many other applications. All that is required is a slight modification to the pipework design and the installation of a siphon breaker valve. The benefits are recouped whenever the plant is running.

For detailed product information, including mode of operation, see the downloadable publication on the right hand side of this page or Contact Us.

Up arrowTOP Bedford Pumps Ltd - Brooklands - Woburn Road Industrial Estate - Kempston - Bedford - MK42 7UH - England